L60ADIL8-CM | MITSUBISHI Analog input module L60ADIL8-CM

MITSUBISHI L60ADIL8-CM Manual And Instructions
L60ADIL8-CM datasheetPDF datasheet

MITSUBISHI L60ADIL8-CM Product information and technical parameters:
Brand: MITSUBISHI
Name: Analog input module
Model: L60ADIL8-CM
Number of input channels: 8ch.
Input current: DC0 ~ 20mA.
Conversion speed: 1ms/ch.
Resolution: 1/8000.
By shifting the function easily when the system starts to fine tune the movement function.
Shift the set value to (shift to) the function of the digital output value.
If you change the conversion value, the value is reflected in real time to the value of the scale (numeric value),
Can easily complete the fine-tuning of the system startup.
Extended detection method based on usage
Anomaly detection and extension of input signal
The detection method of the abnormal detection function of the input signal can be extended to detect the abnormal detection function of the input signal which is outside the range of the set range.
For the detection of the lower limit or the upper limit of the input signal abnormality, or when the detection of the broken line is performed.
Enter range extension
Range of scalable input range.
Combined with the abnormal detection function of the input signal, the broken line can be easily detected.

Convert connectors to fast connectors.
According to the location of the connection equipment distribution module. Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module. Positive common end use. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output MITSUBISHI L60ADIL8-CM. AnyWireASLINK master station L60ADIL8-CM
Transmission distance: the longest 200m.
Data input and output: up to 512 points.
Connect up to 128 units.
Enter 256 points, 256 points out of the output.
Connecting the input and output of the sensor to the programmable controller.
Ultra small sensor can be freely configured to control the input and output of 512 points MITSUBISHI L60ADIL8-CM.
In addition, the sensor can be supplied with a AnyWireASLINK transmission line (2 lines) by means of communication,
So as to facilitate additional sensor.
And can also be through the engineering software Works2 GX batch management sensor disconnection detection and from the station module settings, etc.,
Can significantly reduce the engineering hours.
Basic composition.
AnyWireASLINKAnyWireASLINK can be selected according to the load current of 2 wire or 4 wire from the station module MITSUBISHI L60ADIL8-CM.
In addition to the 2 wire type, the local power supply can be connected with the 4 wire type mixed use.
2 wire type.
The load current is less than that of the hour, by using the non isolated 2 wire type from the station module,
Easy connection without using local power supply.
4 wire type
By using isolated 4 wire type from the station module, the local power supply can be used,
Can support the use of more current load. "Universal output function: leakage type.
Program capacity: 20K step.
Basic operations processing speed: 60ns.
Communication interface: USB/RS-232.
Control mode: stored procedure repeated operation.
Input / output points: 1024 points.
End cap.
Unable to install display module (L6DSPU-C-CM), RS-232 adapter, RS-422/485 adapter.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be acccurately calculated " L60ADIL8-CM.
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming coontrol, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators L60ADIL8-CM. "