MITSUBISHI
Home >> Products >> MITSUBISHI >> L series PLC >> Positioning movement module >> LD75P2-CM | MITSUBISHI Positioning module LD75P2-CM

LD75P2-CM | MITSUBISHI Positioning module LD75P2-CM

MITSUBISHI LD75P2-CM Manual And Instructions
LD75P2-CM datasheetPDF datasheet

MITSUBISHI LD75P2-CM Product information and technical parameters:
Brand: MITSUBISHI
Name: Positioning module
Model: LD75P2-CM
Open collector output.
Axis of control: 2.
Maximum output pulse: pulse/s 200k.
Location data: 600 data / axis.
Max link distance: 2m.
With the parameter setting, the synchronization control can be easily realized. Do not need to write complex procedures.
Start / stop with synchronous control of the shaft.
Synchronous control of the axis and the positioning of the axis can coexist.
Through the clutch, the movement of the main shaft can be transferred to the output shaft.
Simple implementation of synchronization control.
Cam control is more simple
Cam data can easily create a variety of patterns.
Can be simple to achieve the gear, shaft, transmission, cam and other mechanical mechanisms to replace the software synchronization control.
It is not subject to the limitation of the concept of the electronic cam control so far, and can use the cam with high degree of freedom.
The stroke, speed, acceleration and beat can be confirmed on the graph, and the setting is carried out at the same time.
Can also be through the cam data thumbnail display, easy to confirm the cam data has been created.
Can import and export the cam data in CSV format.

Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.The terminal row is converted to e-CON.Control axis: maximum 16 axes.
Operation cycle: 0.88ms, 1.77ms.
Interpolation function: linear interpolation (maximum 4 axis), 2 axis arc interpolation.
Color signal: 4 points MITSUBISHI LD75P2-CM.
Color detecting set: 16 set.
Only need to use the PLC program can easily achieve synchronous control, cam control, speed and torque (push pressure control) and other advanced motion control LD75P2-CM
Equipped with standard synchronous encoder and color detection function necessary function.
Can be no procedures for setting. Strong support for MELSOFT.
Can fully apply LD77MH of the old program MITSUBISHI LD75P2-CM.
Let motion control more simple. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Convert connectors to fast connectors.
According to the location of the connection equipment distribution module. Input points: 32 points.
Rated input voltage: DC24V.
Common way: 32 point / public end.
Input / output occupied points: 32 points (I/O distribution: 32 points) MITSUBISHI LD75P2-CM.
External wiring connection mode: 40 pin connector.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the part can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on. CC-Link/LT master station.
Transmission speed: 2.5Mbps.
Remote input / output: 1024 points.
16 point mode.
In the cabinet, the device can also respond to high speed.
CC-Link/LT link scan ttime to reach the highest 1 LD75P2-CM. 2ms (2.5Mbps) at 64 stations,
Excellent response performance is achieved.
Can be selected according to the transmission distance 2.5Mbps, 625kbps, 156kbps.
Comfortable environment without network awareness.
Paraameter settings that do not require any trouble LD75P2-CM.
Moreover, the transmission speed only through the master module to set, can easily use the remote I/O.


...More relevant models >>>>