MITSUBISHI
Home >> Products >> MITSUBISHI >> Q series PLC >> C language CPU >> Q12DCCPU-V | MITSUBISHI C language CPU Q12DCCPU-V

Q12DCCPU-V | MITSUBISHI C language CPU Q12DCCPU-V

MITSUBISHI Q12DCCPU-V Manual And Instructions
Q12DCCPU-V datasheetPDF datasheet
Q12DCCPU-V datasheetPDF datasheet
Q12DCCPU-V Special InstructionsStrctured Programming Manual
Q12DCCPU-V Application FunctionsStrctured Programming Manual
Q12DCCPU-V Common InstructionsStrctured Programming Manual
Q12DCCPU-V FundamentalsStrctured Programming Manual
Q12DCCPU-V Multiple CPU SystemUser's Manual
Q12DCCPU-V Function Explanation, Program FundamentalsUser's Manual
Q12DCCPU-V Hardware Design, Maintenance and InspectionUser's Manual
Q12DCCPU-V Structured TextProgramming Manual
Q12DCCPU-V MELSAP-LProgramming Manual
Q12DCCPU-V SFCProgramming Manual
Q12DCCPU-V PID Control InstructionsProgramming Manual
Q12DCCPU-V Common Instructions 1/2Programming Manual
Q12DCCPU-V Structured Text(ST)Programming Guide Book

MITSUBISHI Q12DCCPU-V Product information and technical parameters:
Brand: MITSUBISHI
Name: C language CPU
Model: Q12DCCPU-V
Input / output points: 4096 points.
You can use the CF card.
Version OS:VxWorks 6.4.
Simply insert the SD memory card, you can automatically record.
Simply insert the SD in the CPU to save the record setting file, you can automatically start recording.
Even when remote data collection is required,
After receiving a record setting file by mail and copy it to the SD memory card,
Can immediately start recording.
Automatically transfer the record file to the FTP server
Simply by recording the configuration tool to carry out a simple setup,
A data record file stored on the SD memory card can be sent to the FTP server.
Because the record server can handle multiple files, it can reduce the task of management and maintenance.
When a failure occurs, it can quickly respond to.
Simply extract the data associated with the problem, do not have to spend a lot of time to filter a large number of diagnostic data,
So it can quickly determine the cause of the failure, and make the solution.

Output: 2 channels.
Input (resolution): 0~4000; -4000~4000; 0~12000; -12000~12000; -16000~16000.
Output: DC-10~10V; DC0~20mA.
Conversion speed: 80 s/1 channel.
18 point terminal station.
Transformer isolation between power supply and output.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc MITSUBISHI Q12DCCPU-V. .
Standard analog input module.
Isolated analog input module Q12DCCPU-V
No external isolation amplifier required.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module.
The possibility of expanding control with intelligent function.
Providing a variety of analog modules, is the ideal choice for process control applications MITSUBISHI Q12DCCPU-V.
Can also meet the needs of high speed, high precision control.
Most suitable analog modules for high speed conversion control.
Can provide a variety of analog and digital analog conversion module products.
These modules have a variety of functions, in the connection of equipment, to achieve the greatest flexibility.
Can meet the inverter control, such as high-speed conversion needs.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location MITSUBISHI Q12DCCPU-V.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control. Used for a common positive input module (3 line type).1 axis, differential drive output type.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis.
Maximum pulse output: 1Mpps.
40 pin connector.
Positioning module.
Open collector output.
Differential driver output.
Can also meet the needs of high speed, high precision control.
Most suitable analog modules for high speed conversion control.
Can provide a variety of analog and digital analog conversion module products.
These modules have a variety of functions, in the connection of equipment, to achieve the greatest flexibility.
Can meet the inverter control, such as high-speed conversion needs.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control.
The possibility of expanding control with intelligent function.
Providing a variety of analog modules, is the ideal choice for process control applications.
Based on thee use of open collector outputs and differential drive output type 2 types Q12DCCPU-V.
Differential driver output type positioning module can transmit high speed instruction pulse (up to 4Mpps) to the servo amplifier reliably,
Transmission distance of up to 10 meters, to achieve high speed and high precision control Q12DCCPU-V.
(the command pulse of the open collector positioning module is highest 200kpps.)


...More relevant models >>>>