MITSUBISHI
Home >> Products >> MITSUBISHI >> Ans/QnAs series PLC >> CPU host >> A172SHCPU | MITSUBISHI CPU unit A172SHCPU

A172SHCPU | MITSUBISHI CPU unit A172SHCPU

MITSUBISHI A172SHCPU Manual And Instructions
A172SHCPU datasheetPDF datasheet
A172SHCPU SV22(VIRTUAL MODE)Programming Manual
A172SHCPU Common InstructionsProgramming Manual
A172SHCPU Dedicated InstructionsProgramming Manual
A172SHCPU FundamentalsProgramming Manual

MITSUBISHI A172SHCPU Product information and technical parameters:
Brand: MITSUBISHI
Name: CPU unit
Model: A172SHCPU

Input type: AC.
Input points: 16 points.
Input voltage: AC100-120V.
Input current: 6mA.
Connection mode: terminal row.
Common common point: 16.
The instruction list programming language is a programming language similar to assembly language mnemonic,
As well as assembly language by the operation code and the number of operations MITSUBISHI A172SHCPU.
In the case of the computer for the PLC handheld programmer compile user program A172SHCPU
At the same time, the programming language of the instruction list corresponds to the ladder diagram programming language,
In PLC programming software can be converted to each other. Figure 3 is the instruction sheet corresponding to the ladder diagram of figure 2PLC.
The characteristics of instruction table programming language is used to represent mnemonic operation function,
Easy to remember, easy to grasp;
In the handheld programmer on the keyboard using the mnemonic representation, easy to operate, can be programmed in computer;
There is a one-to-one correspondence between the ladder diagram and the ladder diagram MITSUBISHI A172SHCPU. Its characteristics are basically consistent with the ladder diagram language MITSUBISHI A172SHCPU. Cable length: 1.2 meters.
Extending cable to connect CPU main substrate and extended substrate,
According to the model can provide different cable length,
If you need to connect the AnN type expansion substrate is required,
Selection of A1SC05NB (A1SC07NB) cable. Temperature sensor: PT100, 3 wire system.
The A1S62RD3 and A1S62RD4 temperature sensor input modules allow the platinum resistance temperature sensing element to be directly connected to the PLC,
This component converts a signal from a temperature measuring element to a numeric value that represents a temperature measurement value,
This temperature value can be used for the control process.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of.
The response time of PLC is the interval between the time of the change of the external output signal of tthe PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the usse of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on A172SHCPU A172SHCPU.
This phenomenon is called the I/O delay time effect.