L02SCPU-CM | MITSUBISHI cpu module L02SCPU-CM

MITSUBISHI L02SCPU-CM Manual And Instructions
L02SCPU-CM datasheetPDF datasheet
L02SCPU-CM Common InstructionsProgramming Manual
L02SCPU-CM Special InstructionsProgramming Manual
L02SCPU-CM Application FunctionsProgramming Manual
L02SCPU-CM Common InstructionsProgramming Manual
L02SCPU-CM Structured Text(ST)PROGRAMMING Guide Book
L02SCPU-CM Structured TextProgramming Manual
L02SCPU-CM MELSAP-LProgramming Manual
L02SCPU-CM Structured TextProgramming Guide
L02SCPU-CM PID Control InstructionsProgramming Manual
L02SCPU-CM Special InstructionsProgramming Manual
L02SCPU-CM Common InstructionsProgramming Manual
L02SCPU-CM Application FunctionsProgramming Manual
L02SCPU-CM ApplicationUser's Manual
L02SCPU-CM Structured TextProgramming Manual

MITSUBISHI L02SCPU-CM Product information and technical parameters:
Brand: MITSUBISHI
Name: cpu module
Model: L02SCPU-CM
"Universal output function: leakage type.
Program capacity: 20K step.
Basic operations processing speed: 60ns.
Communication interface: USB/RS-232.
Control mode: stored procedure repeated operation.
Input / output points: 1024 points.
End cap.
Unable to install display module (L6DSPU-C-CM), RS-232 adapter, RS-422/485 adapter.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ".
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators. "

Maximum transmission speed: 115.2kbps.
DC5V internal consumption current: 0.02A.
GOT connection.
MELSOFT connection.
Communication protocol support function serial communication function. Control axis: maximum 4 axes.
Operation cycle: 0.88ms.
Interpolation function: linear interpolation (maximum 4 axis), 2 axis arc interpolation MITSUBISHI L02SCPU-CM.
Color signal: 4 points.
Color detecting set: 4 set L02SCPU-CM
Only need to use the PLC program can easily achieve synchronous control, cam control, speed and torque (push pressure control) and other advanced motion control.
Equipped with standard synchronous encoder and color detection function necessary function.
Can be no procedures for setting. Strong support for MELSOFT MITSUBISHI L02SCPU-CM.
Can fully apply LD77MH of the old program.
Let motion control more simple. Number of input channels: 8ch.
Input temperature resistance: Pt1000, Pt100, JPt100, Pt50, Ni500, Ni120, Ni100, Cu100, Cu50.
Conversion speed: 40ms/ch.
Resolution: 0.1.
Status of connected devices by means of alarm monitoring.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm MITSUBISHI L02SCPU-CM.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement.
High speed, smooth continuous analog output.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulated according to the set conversion period.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output. Input points: 16 points.
Rated input voltage: DC24V.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: 16 points).
External wiring connection: 18 point terminal.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computter,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the parrt can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on L02SCPU-CM L02SCPU-CM.


...More relevant models >>>>